8453449833
Replace the inaccurate CFM-based formula with nozzle-primary tables sourced from industry standard abrasive blast cleaning references: - Pressure pot: midpoints averaged from two reference tables (#4 nozzle: 115 sqft/hr, #5: 175 sqft/hr, etc.) - Siphon cabinet: dedicated siphon cabinet reference table (#4 nozzle: 125 sqft/hr, #3: 75 sqft/hr, etc.) - SiphonPot: 80% of pressure pot rate (open gravity feed, no enclosure) - WetBlasting: 60% of pressure pot rate (water-media reduces velocity) CFM is removed from the rate formula entirely — nozzle size determines throughput and CFM draw, so CFM is a consequence of nozzle choice, not an independent variable. Override field still bypasses formula for shops that have measured their own throughput. Also corrects TierDefaults nozzle/CFM pairings which were mismatched (e.g. Small tier had 40 CFM assigned to a #5 nozzle that needs 150 CFM). Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>